Contract notice

Information

Published

Date of dispatch of this notice: 14/02/2022

Expire date: 23/03/2022

External Reference: 2022-299652

TED Reference: 2022/S 035-087605

Contract notice

[NoticeContract]

[Directive201424]

[Section1]: [Ca]

I.1)

[NameAddressContact]

Dundalk Institute of Technology
N/A
Dublin Road
Co. Louth
Dundalk
IE
[Contactpoint]: Susan Gorman
[AddressPhone]: +353 429370200
[AddressEmail]: susan.gorman@dkit.ie
[Nutscode]:  IE -  IRELAND
[Internets]:
[UrlGeneral]: http://www.dkit.ie

I.3)

[InfoTendering]

[AddressObtainDocs]:  
http://irl.eu-supply.com/app/rfq/rwlentrance_s.asp?PID=207489&B=ETENDERS_SIMPLE
[AddressFurtherinfo]
[AsContactsAbove]:  
[AddressSendTendersRequest]
[AddressSendTendersRequest]
[AddressToAbove]
I.4)

[CaType]

[MaintypePublicbody]
I.5)

[Mainactivity]

[MainactivEducation]

[Section2]: [Object]

II.1)

[QuantityScopeContract]

II.1.1)

[TitleContract]

HASS/HALT Environmental Chamber
II.1.2)

[CpvMain]

38970000  - 
II.1.3)

[TypeContract]

[Supplies]
II.1.4)

[DescrShort]

HASS/HALT Environmental Testing Chamber
Essential Technical Criteria of the HASS/HALT Environmental Testing Chamber include:
• Large vibrating table with suitably threaded holes for fixing test pieces.
• Six degrees of freedom vibration to allow for random vibration.
• Table capacity of minimum 200kg.
• Vibration rate up to 60gRMS.
• Vibration table should be fully accessible.
• A minimum of 2 windows for inspection.
• At least one access port for wiring, piping, etc.
• Heating system is typically electric.
• Cooling systems is liquid nitrogen.
• Temperature range +80°C to -50°C.
• Temperature rate is typically 70°C/minute.
• Built in thermocouples and thermostats with the capability of utilising additional thermostats.
• Accelerometer with additional channels for further accelerometers.
• Control software and data acquisition.
II.1.5)

[ValueMagnitudeEstimatedTotal]

[ValueExclVat]: 201130.00  EUR
II.1.6)

[LotsInfo]

[DivisionLots]: [No]
II.2)

[Description]

II.2.2)

[CpvAdditional]

38970000  - 
II.2.3)

[PlacePerformance]

[Nutscode]:  IE -  IRELAND
[MainsiteplaceWorksDelivery]:  
DKIT
II.2.4)

[DescrProcurement]

HASS/HALT Environmental Testing Chamber
Essential Technical Criteria of the HASS/HALT Environmental Testing Chamber include:
• Large vibrating table with suitably threaded holes for fixing test pieces.
• Six degrees of freedom vibration to allow for random vibration.
• Table capacity of minimum 200kg.
• Vibration rate up to 60gRMS.
• Vibration table should be fully accessible.
• A minimum of 2 windows for inspection.
• At least one access port for wiring, piping, etc.
• Heating system is typically electric.
• Cooling systems is liquid nitrogen.
• Temperature range +80°C to -50°C.
• Temperature rate is typically 70°C/minute.
• Built in thermocouples and thermostats with the capability of utilising additional thermostats.
• Accelerometer with additional channels for further accelerometers.
• Control software and data acquisition.
II.2.5)

[AwardCriteria]

[AwardCriteriaDescriptive]
II.2.6)

[ValueMagnitudeEstimated]

[ValueExclVat]: 201130.00  EUR
II.2.7)

[DurationContractFrameworkDps]

[Indays]: 90
[RenewalsSubject]: [No]
II.2.10)

[VariantsInfo]

[VariantsAccepted]: [No]
II.2.11)

[OptionsInfo]

[Options]: [No]
II.2.13)

[EuProgrInfo]

[EuProgrRelated]: [No]

[Section3]: [InfoLegal]

III.1)

[ConditionsParticip]

III.1.2)

[EconomicFinancialStanding]

[CriteriaSelectionDocs]
III.1.3)

[TechnicalCapacity]

[CriteriaSelectionDocs]
III.2)

[ConditionsContract]

[Section4]: [Procedure]

IV.1)

[Description]

IV.1.1)

[TypeProcedure]

[ProctypeOpen]
IV.1.8)

[GpaInfo]

[GpaCovered] : [No]
IV.2)

[InfoAdmin]

IV.2.2)

[LimitReceiptTendersReqPart]

[Date]:  23/03/2022
[Time]:  17:00
IV.2.4)

[LanguagesAllowed]

[Language_EN]
IV.2.6)

[MinTimeMaintain]

[DurationMonths] : 3  ([FromStatedDate])
IV.2.7)

[OpeningConditions]

[Date]:  23/03/2022
[Time]:  17:00
[OpeningPlace]:  
Dundalk Institute of Technology

[Section6]: [InfoComplement]

VI.1)

[RecurrenceInfo]

[RecurrentProcurement]:  [No]
VI.2)

[InfoEworkflow]

[EorderingUsed]
[EinvoicingUsed]
[EpaymentUsed]
VI.4)

[AppealsProcedure]

VI.4.1)

[AppealsBody]

Dundalk Institute of Technology
Dublin Road
Dundalk
A91 K584
IE