II.1)
Scope of the procurement
High Speed Transient / Power Quality Recorders
Reference number:
ENQEIR580
31644000
-
Miscellaneous data recorders
Supplies
II.1.4)
Short description
This tender process is complete.
EirGrid has procured a supplier of Power Quality/Transient Fault Recorders to be used on the 400 kV, 275 kV, 220 kV and 110 kV Transmission network on the island of Ireland. The recorders shall be installed in transmission stations. The Framework Agreement period will be for an initial duration of five years with the option to extend annually for up to an additional three years, subject always to the satisfactory performance of the supplier.
II.1.6)
Information about lots
This contract is divided into lots:
no
II.1.7)
Total value of the procurement
( Agree to publish? yes )
Value excluding VAT:
1000000.00
EUR
II.2.2)
Additional CPV code(s)
31644000
-
Miscellaneous data recorders
II.2.3)
Place of performance
NUTS code:
IE061 -
Dublin
Main site or place of performance:
Dublin
II.2.4)
Description of the procurement
This tender process is complete.
EirGrid procured a supplier of Power Quality/Transient Fault Recorders to be used on the 400 kV, 275 kV, 220 kV and 110 kV Transmission network on the island of Ireland. The recorders shall be installed in transmission stations and their primary functions will be:
Fault/Event recording in response to under, over and rate-of-change of voltage, current, frequency and active power in addition to remote manual and binary input triggers;
Power Quality measurements, including flicker, unbalance and harmonics measurements up to and including the 50th harmonic; and
Data streaming on a continuous basis for Phasor Monitoring Units (PMU) application.
The recorders shall be capable of receiving GPS time-stamped voltage and current inputs derived from either protection or metering class instrument transformer cores and shall monitor the circuit passively. The recorder, in addition to current and voltage measurements, should provide the following:
Three-phase Active and Reactive Power measurements using the appropriate voltage and current channels for calculation;
Fundamental frequency of voltage measurement. It is desirable that the frequency be calculated using a phase-to-phase voltage; and
Positive, negative and zero phase sequence voltages and currents.
II.2.5)
Award criteria
( Agree to publish? yes )
Criteria below
Quality criterion
-
Name:
Technical Merit & Quality
/
Weighting:
40
Quality criterion
-
Name:
Proposal & Service Delivery Approach
/
Weighting:
20
Quality criterion
-
Name:
Legal
/
Weighting:
5
Cost criterion
-
Name:
Ultimate cost
/
Weighting:
35
II.2.11)
Information about options
Options:
yes
Description of options:
The Framework Agreement period will be for an initial duration of five years with the option to extend annually for up to an additional three years, subject always to the satisfactory performance of the supplier.
II.2.13)
Information about European Union funds
The procurement is related to a project and/or programme financed by European Union funds:
no